TUP500 Series Product Specifications
5-3
(5) Conducted Disturbances Immunity Test
Standards Cited Testing Levels
EN61000-4-6
Level 2
(Voltage: 3 V)
(6) Power Frequency Electromagnetic Field Immunity Test
Standards Cited Testing Levels
EN61000-4-8
Level 1
(Magnetic Field Strength: 1 A/m)
(7) Voltage Drop, Temporary Interruption and Voltage Fluctuation Immunity Tests
Standards Cited Testing Classes
EN61000-4-11
Class 2
0% between 0.5 cycles
0% between 1.0 cycles
70% between 25/30 cycles
0% between 250/300 cycles
(8) Impulse Noise Test
Test Specifications
Tolerance Level When Connected to PC
(ASCII continuous printing)
Voltage: PE Phase 1 kV, L/N Phase 0.5 kV
Pulse Width: 100 ns