OIL
Equivalent AGIP OSO 46
BP ENERGOL HLP-HM 46
ESSO NUTO H 46
INDIAN OIL SERVO SYSTEM HLP 46
SHELL TELLUS S2 M46
ATTENTION
- Disassembling the pump (3) tank (1) to carry out this topping up operation is pro-
hibited.
- The pressure for the extension and retraction of the cylinder rod (6) must not be
adjusted. The nuts (2), (4) on each side of the pump are sealed (red paint).
- Any operation on the circuit must be carried out in absolutely clean conditions.
- Hydraulic oil is not compatible with cam motion oil. The mixture occurs, the cam
motion must be drained completely.
- Operate the leveller in the case where it does not function on a daily basis.
6.2.3 - CLEAN THE FILTER TZM50-NFI001.2
Frequency:
- With each warp change without exceeding 1 month.
6 - Maintenance
46/62 © Stäubli 2013 – F.143.489.04-C 1781 B1 DRC10