EasyManua.ls Logo

Staubli Cam Motion 1781 - 6.2.3 - CLEAN THE FILTER

Staubli Cam Motion 1781
64 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
OIL
Equivalent AGIP OSO 46
BP ENERGOL HLP-HM 46
ESSO NUTO H 46
INDIAN OIL SERVO SYSTEM HLP 46
SHELL TELLUS S2 M46
ATTENTION
- Disassembling the pump (3) tank (1) to carry out this topping up operation is pro-
hibited.
- The pressure for the extension and retraction of the cylinder rod (6) must not be
adjusted. The nuts (2), (4) on each side of the pump are sealed (red paint).
- Any operation on the circuit must be carried out in absolutely clean conditions.
- Hydraulic oil is not compatible with cam motion oil. The mixture occurs, the cam
motion must be drained completely.
- Operate the leveller in the case where it does not function on a daily basis.
6.2.3 - CLEAN THE FILTER TZM50-NFI001.2
Frequency:
- With each warp change without exceeding 1 month.
6 - Maintenance
46/62 © Stäubli 2013 – F.143.489.04-C 1781 B1 DRC10