Connecting the suction line
Connecting the suction line with the self-fastening hose
- When using self-fastening hoses Ø 32 / 38 mm.
1. Screw a hose adapter
clockwise
onto the prelter cover
.
2. Make sure that water from the supply
or drain line does not ow into the
pool.
3. Push the hose end onto the hose
adapter and use the hose clamps to x
the hose in place.
The sucon line is connected.
Connecting the return line
Connecting the return line
When using push-on hoses.
1. Push one hose end onto the connecon for the return line
on the lter cover
.
2. Connect the second end to the connecon on the injecon nozzle of the pool.
The return line
is connected.
Preparing the filter system
1. Remove the stopper on the sucon line if applicable.
2. Check that the sucon line is free and then open the shut-o valve on the sucon
line.
The lter system lls automacally with water because it is below the water level.
3. Let the lter vessel ll completely with water.
4. Bleed the lter system. Open the prelter cover
on the pump slightly by loosening
the threaded ring
unl water ows from the prelter cover.
5. Let the prelter cover ll completely with water.
6. Check the lter system and the connecons for leaks.
In the case of leaks, wrap extra Teon tape around the aected connecons.
49