EDIT PARAMETERS
Parameter
Name
Cold Units
(Stero SU-L)
(Glass Unit:
Stero SG)
Hot Units
(Stero SU-H)
Description
Possible
Values
Default
Values
Low Temp
Alarms
N/A Stero SU-H
Enables or disables a visual
alert on the display that
indicates that the Final Rinse
water temperature is below the
required minimum of 180°F
(82°C). When enabled, a
message will display notifying
the user of this condition after
three consecutive cycles do not
reach the required final rinse
temperature. However,
machine operation will not
change and ware will continue
to wash as expected. After the
temperature increases past the
minimum, the message stops.
When disabled, there will be no
extra message indicating a low
temperature event.
Disabled /
Enabled
Disabled
Add Chem
Alerts
Stero SU-L
Stero SG
Stero SU-H
Disables or enables an audible
and visual alert if chemical is not
being detected.
Disabled
Visual
Audio and
Visual
Audio and
Visual
End Cycle
Audio Alert
Stero SU-L
Stero SG
Stero SU-H
Disables or enables an audible
and visual alert if chemical is not
being detected.
Disabled
Visual
Audio and
Visual
Disabled
Temperature
Units
Stero SU-L
Stero SG
Stero SU-H
Sets the display units to either
Fahrenheit or Celsius.
Fahrenheit
Celsius
Fahrenheit
Language
Stero SU-L
Stero SG
Stero SU-H
Sets the language on the
display.
English
French
Spanish
English
Exit Menu
Stero SU-L
Stero SG
Stero SU-H Exits Edit Parameters mode.
SG, SU-L, SU-H DISHWASHERS - SERVICE PROCEDURES AND ADJUSTMENTS
F45577 (1215) Page 28 of 59