SOAP PROGRAMMING (7627)
Service Programming
•
EDIT PARAMETERS
•
PRIME PUMPS
• EXIT MENU
1. Press MENU button on keypad.
2. Enter SERVICE MENU.
3. Enter Service code 7627.
EDIT PARAMETERS
Parameter
Name
Cold Units
(Stero SU-L)
(Stero Glass
Washer SG)
Hot Units
(Stero SU-H)
Description Possible Values Default Values
Detergent
Pump
Stero SU-L
Stero SG
Stero SU-H
Detergent pump
option.
Disabled / Enabled Enabled
Detergent
Flow Rate
(Amount)
Stero SU-L
Stero SG
Stero SU-H
Detergent flow rate
(amount) measured
in mL per cycle.
OFF through 20.0 mL 7.9 mL
Rinse Aid
Pump
Stero SU-L
Stero SG
Stero SU-H
Rinse Aid pump
operation.
Disabled / Enabled Enabled
Rinse Aid
Flow Rate
(Amount)
Stero SU-L
Stero SG
Stero SU-H
Rinse Aid flow rate
(amount) measured
in mL per cycle.
OFF through 8.8 mL 1.8 mL
Sanitizer
Flow Rate
(Amount)
Stero SU-L
Stero SG
N/A
Sanitizer flow rate
(amount) measured
in mL per cycle.
Off to 100 mL 60 mL
Detergent
Threshold
Stero SU-L
Stero SG
Stero SU-H
Sets detection
amount.
Sets maximum
allowable chemical
sense reading (mV)
for detergent.
0-4000 (by 100's) 1100
Rinse Aid
Threshold
Stero SU-L
Stero SG
Stero SU-H
Sets detection
amount.
Sets maximum
allowable chemical
sense reading (mV)
for rinse aid.
0-4000 (by 100's) 2500
SG, SU-L, SU-H DISHWASHERS - SERVICE PROCEDURES AND ADJUSTMENTS
Page 25 of 59 F45577 (1215)