SU-L & SG WIRING DIAGRAM
NOTE: Wiring diagrams are for both SU-L & SG.
SUPPLY
* AMP** NOTES
120/60/1 C 20 USE L1, N
ALIMENTATION * A** REMARQUES
120/60/1 C 20 UTILISER L1, N
*C = CHEMICAL (NON BOOSTER)
* = CHIMIQUE (NON SURVOLTEUR)
** Minimum supply conductor ampacity / maximum protective device.
** INTENSITÉ D'ALIMENTATION MINIMALE AU CONDUCTEUR / DEPOSITIF DE PROTECTION MAXIMALE
NOTE: For supply connection use copper wire only, suitable for 90°C min.
AVIS: POUR LES CONNEXIONS À L'ALIMENTATION, UTILISER UNIQUEMENT DES FILS DE CUIVRE
SUPPORTANT AU MOINS 90°C.
NOTE: Torque power lugs to 40-45 inch pounds.
AVIS: SERRER LES COSSES DE PUISSANCE À UN COUPLE DE 40-45 LB-PO
For continued protection against fire, replace only with same type and rating fuse.
A VERTISSEMENT: POUR UNE PROTECTION CONTINUE CONTRE LE FEU, REMPLACER LE FUSIBLE
UNIQUEMENT PAR UN FUSIBLE DE MÊME TYPE ET DE MÊME CALIBRE.
Electrical and grounding connections must comply with the applicable portions of the National Electrical
Code, ANSI/NFPA 70, latest edition, and /or other local electrical codes.
A VERTISSEMENT
Le raccordement électrique et la mise à la terre doivent être conformes aux normes concernées du code canadien
del'électricité et/ou de tout autre code d'électricité en vigueur.
SG, SU-L, SU-H DISHWASHERS - ELECTRICAL OPERATION
Page 43 of 59 F45577 (1215)