EasyManua.ls Logo

Stihl MS 341

Stihl MS 341
110 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Online version - not for reprint
64 MS 341, MS 361, MS 361 C
Troubleshooting chart – b 4.2
The replacement spring comes
ready for installation and is secured
in a frame.
Removing
Wear a face shield and work gloves.
Remove the rope rotor – b 8.4
: Use suitable pliers to grip the
outer spring loop and lift it up.
Take the rewind spring out of the
fan housing.
Remove any remaining pieces of
spring from the fan housing.
VA
212RA107
Installing
Lubricate the spring with a few
drops of STIHL special lubricant
before installation – b 16.
: Position replacement spring with
frame (1) in the fan housing.
VA
212RA108
1
: Position suitable tools on the
recesses (arrows) and push the
spring into its seat in the fan
housing.
If the rewind spring pops out during
installation, fit it in the installing tool
1116 893 4800 as follows:
: Arrange the rewind spring as
shown in the illustration.
212RA306
VA
: Position the anchor loop about
25 mm from the edge of the
spring housing.
212RA285
VA
: Fit the rewind spring in the spring
housing in the counterclockwise
direction, starting from outside
and working inwards.
Place the spring housing in the
fan housing.
212RA286
VA
Press the spring loop into the
recess in the fan housing at the
same time.
Install the rope rotor – b 8.4
Reassemble all other parts in the
reverse sequence.
8.9 Replacing the Rewind
Spring