Online version - not for reprint
95MS 341, MS 361, MS 361 C
– Remove spring between front
handle and cylinder – b 9.1.1
: Unscrew the hex nut (1).
: Remove the washer (2).
VA
212RA254
2
: Push back the grommet (1).
: Disconnect the wire (2) from the
heater switch.
212RA298
VA
2
1
: Push the heater switch (1) with
the ground wire ring terminal (2)
inwards and pull it out forwards.
212RA299
VA
1 2
: Take out the screw (1).
: Remove the ground wire (2).
Terminals and ground wire must not
be damaged or corroded. Replace if
necessary.
212RA300
VA
2
1
Install in the reverse sequence.
– Push ground wire ring terminal
over the thread of the heater
switch.
– Place the heater switch in the
tank housing.
The crimping of the ring terminal
must be positioned between the
tank housing and heater switch.
When fitting the heater switch (1),
pay attention to correct installed
position (arrows). The switch seat is
not symmetrical.
212RA302
VA
1
– Fit the washer (1) and hex nut (2).
– Check that the ground wire ring
terminal (3) locates fully against
the heater switch’s contact face.
212RA303
VA
2
1
3
Fit the ground wire (1) so that the
ring terminal’s crimping faces up.
Terminals and ground wire must not
be damaged or corroded. Replace if
necessary.
212RA301
VA
1
14.6 Heater Switch