Environmental Requirements
General
Model: Origin One
Process type: P3 (Programmable Photopolymerization)
Materials: Photocurable materials from the Stratasys ecosystem materials partners
Build Dimensions (W x D x H) (May be slightly reduced to increase dimensional accuracy)
192mm × 108mm × 370mm
7.56” × 4.25” × 14.57”
Feature Resolution: Typically <50μm (material and design-dependent)
Process Energy: UV (385nm) and Thermal
Resin Tray Capacity: 15 - 65 fl oz (2 liters max)
Supported File Types: STL and Zip of PNG images
Physical
System Dimensions (W x D x H)
Printer Crated 250 pounds (113.5 kg) Width: 30 inches (762 mm)
Depth: 35 inches (889 mm)
Height: 55 inches (1397 mm)
Printer Uncrated 180 pounds (81.6 kg) Width: 19 inches (483 mm)
Depth: 20 inches (508 mm)
Height: 44 inches (1118 mm)
Power Requirements: 90 - 264 VAC, 50 - 60 HZ, 700 W, 1 phase
Connectivity: Ethernet
Environmental
The Origin One printer operating temperature shall be in the range of 59°F to 86°F (13°C to
30°C), with relative humidity range of 30% to 70% non-condensing.