EasyManua.ls Logo

Stratasys Origin One - Lubricating the Linear Drive

Stratasys Origin One
88 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Cleaning Lubricating the Linear Drive
Page 55
© Copyright 2022 Stratasys. All rights reserved.
5. Reinstall the fan filter cover and replacement filter. Engage both fan filter cover clips to
secure the fan filter cover to the back panel.
Figure 4: New fan filter
Lubricating the Linear Drive
Frequency
Every 12 months
Required Tools
Syringe with Linear Drive Grease
Flashlight
Screwdriver

Table of Contents

Related product manuals