28 Sun Fire T1000 Server Installation Guide January 2006
1. If this is the first time the system has been powered on, use the password
command to set the admin password.
After the admin password has been set, on subsequent reboots, the sc login prompt
is displayed.
2. Enter admin for the login name followed by your password.
To Configure the System Controller Network
Management Port
To access the system controller using the network for the first time, you must first
configure the SC network management port through the SC serial management port.
You set these network parameters according to the specific details of your network
configuration:
if_network Specified whether the SC is on the network or not
netsc_ipaddr IP address of the system controller
netsc_ipgateway IP address of the gateway for the subnet
netsc_ipnetmask Netmask for the system controller subnet
.........................
TTYD - - PASSED
TTYC - - PASSED
MEMORY - - PASSED
MPC885 - - PASSED
sc> password
password: Changing password for admin
Setting password for admin.
New password: new-password
Re-enter new password: new-password
sc>
TTYD - - PASSED
TTYC - - PASSED
MEMORY - - PASSED
MPC885 - - PASSED
Please login: admin
Please Enter password: password
(Press Return twice)
sc>