8 Sun Fire V890 Server Rackmounting Guide • May 2004
Tools, Equipment, and Documentation
Required
The following tools, equipment, and documentation are required when
rackmounting the server:
■ Phillips No. 2 screwdriver
■ Phillips No. 1 screwdriver
■ Level
■ Flat blade screwdriver
■ Adjustable wrench
■ Masking tape or felt tip pen
■ Antistatic wrist strap
■ Antistatic mat
■ Sun Fire V890 Server Owner’s Guide
■ Sun Fire V890 Server Service Manual
Preparing the Server
To prepare the server for rackmounting, a qualified service technician should
complete the following tasks:
■ Power off the system and disconnect the server’s power cords, network cables,
and I/O cables. See the Sun Fire V890 Server Service Manual for instructions.
■ Remove all power supplies, CPU/Memory boards, I/O fan trays, and CPU fan
trays. See “Remove Components” on page 9.
■ Remove the side door handles. See “Remove the Handle From Each Side Door”
on page 10.
■ Remove the fenders and lower side panels. See “Remove the Fenders and Lower
Side Panels” on page 13.
■ Install the lifting handles. See “Install the Lifting Handles” on page 15.
■ Attach the cable management bracket to the back of the server. See “Attach the
Cable Management Bracket to the Server” on page 16.