18 Sun Fire V890 Server Rackmounting Guide May 2004
Preparing the Cabinet
Make sure the operating location complies with the Sun Fire V890 server
requirements and the cabinet requirements. See Appendix A of this guide and the
cabinet documentation for information.
1. Be sure the cabinet is stabilized so that the cabinet cannot move or tip forward.
If there are feet beneath the cabinet to prevent it from rolling, be sure the feet are
fully extended downward to the floor.
Stabilize the cabinet using the stabilizing mechanisms provided with the cabinet.
See the instructions provided with the cabinet.
2. Open the front and rear doors.
See the instructions provided with the cabinet.
3. Remove (if applicable) the front and rear doors and the side panels of the cabinet.
See the instructions provided with the cabinet.
Installing the Tray Assembly Into the
Cabinet
To install the tray assembly into the cabinet, complete these tasks:
If necessary, adjust the rear brackets on the tray assembly slides for the depth of
the cabinet. See “Adjust the Rear Brackets” on page 19
Determine the vertical position of the server in the cabinet. See “Determine the
Vertical Position of the Server in the Cabinet” on page 20.
Attach the tray assembly to the cabinet rails. See “Attach the Tray Assembly to
the Cabinet” on page 21.

Table of Contents

Other manuals for Sun Microsystems Sun Fire V890

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sun Microsystems Sun Fire V890 and is the answer not in the manual?

Sun Microsystems Sun Fire V890 Specifications

General IconGeneral
BrandSun Microsystems
ModelSun Fire V890
CategoryServer
LanguageEnglish

Related product manuals