30 Sun Fire V890 Server Rackmounting Guide May 2004
Installing Trim Strips
The lower decorative panels (trim strips) were removed when you removed the
lower side panels. To restore the trim strips:
1. Locate the two trim strips provided in the rackmounting kit.
2. Attach one trim strip to the right front cabinet rail and one trim strip to the left
front cabinet rail.
Using the two captive screws, attach each trim strip.
If only one screw on each trim strip aligns with a rail hole, use one screw to attach
each trim strip to each front rail.
Restoring the Cabinet
1. Replace the front and back doors of the cabinet, if applicable.
See the instructions provided with the cabinet.
2. If you removed the side panels from the cabinet, do not replace them until you
connect and route the server cables.
Caution To prevent the cabinet from tipping forward, do not attempt to roll or
move the cabinet after installing the server in the cabinet.
!