38 Sun Fire V880 Server Rackmounting Guide May 2004
Flat blade screwdriver
Adjustable wrench
Masking tape or felt tip pen
Antistatic wrist strap
Antistatic mat
Sun Fire V890 Server Owners Guide
Sun Fire V890 Server Service Manual
Preparing the Server
To prepare the server for rackmounting, complete the following tasks:
Power off the system and disconnect the server’s power cords, network cables,
and I/O cables. See the Sun Fire V890 Server Service Manual for instructions.
Remove all power supplies, CPU/Memory boards, I/O fan trays, and CPU fan
trays. See “Remove Components” on page 38.
Remove the side door handles. See “Remove the Handle From Each Side Door”
on page 40.
Remove the fenders and lower side panels. See “Remove the Fenders and Lower
Side Panels” on page 42.
Install the lifting handles. See “Install the Lifting Handles” on page 45.
Remove Components
In order for four persons to lift the server safely, you must reduce the weight of the
server before you attempt to install it into the cabinet. To reduce the weight of the
server, a qualified service technician should remove the following components:
All power supplies
All CPU/Memory boards
All CPU fan trays
All I/O fan trays
See the Sun Fire V890 Server Service Manual for component removal procedures.
Caution Do not open. Qualified Service Personnel Only. Failure to take this
precaution may result in personal injury and system damage.