116
B. How to set the Y-axis original point
Move the upper feed plate to the middle of the Y-axis direction.
After adjusting Y axis expedition detection plate comes to center of sensor by unfastening joint
screw of Y sensor bracket, fasten the joint screw as shown in the figure.
15) How to Set the Original Point of X-Y
A. How to set the original point of the X-axis
Remove the lower feed plate, X-fixed cover, and transport cover.
Place the upper feed plate center in the middle of the X-axis direction.
Unfasten the two screws of the X-axis original point detecting sensor supporting plate and have the
X-axis original point detecting plate on the X-Y transfer system placed in the center of the sensor
as shown in the picture. Then, tighten the screw with the + driver.









