E. Table leg holder
Place dustproof rubber ② on the bottom of
level adjuster ①.
Put up by turning ⓑ level adjuster ① until
caster ④ starts no load operation.
Fix the level adjuster ① by tightening nut
after installation.
F. How to attach air presser control part.
Connect air hose ② to quick joint socket ①.
Connect quick joint socket ① and quick joint plug ③.
After inflow the air by opening ⓒ finger valve ④, adjust air pressure to 5.0~5.5kgf/cm2
(0.49~0.54MPa).
[ Reference ]
Closing the finger valve after using it, the remaining air is automatically exhausted and the remaining
pressure is indicated 0kgf/㎤(0MPa).
[ Caution ]
Please work on condition of power off to prevent safety accident.
[ Caution ]
In case that the air pressure falls during operation (less 3.5 kgf/cm2), an error message is displayed
and operation of machine stops.
error message: Err 24 (Low Pressure!}