6-26 ELECTRICAL SYSTEM
SIDE-STAND RELAY INSPECTION
First check the insulation between D and E terminals with the
tester. Then apply 12 V to terminals D and C (+ to D and - to
C) and check the continuity between D and E. If there is no
continuity, replace the turn signal/side-stand relay with a new one.
# 09900-25008: Multi circuit tester set
* Tester knob indication: Continuity test (+)
DIODE INSPECTION
Measure the voltage between the terminals using the multi cir-
cuit tester. Refer to the following table.
# 09900-25008: Multi circuit tester set
, Tester knob indication: Diode test (
--
--
-)
NOTE:
If the multi circuit tester reads under 1.4 V, replace its battery
when the tester probes are not connected.
Unit: V
+ Probe of tester to:
C, BA
C, B 1.4 – 1.5
A 0.4 – 0.6
- Probe of
tester to:
Side-stand relay
Diode
Tu r n
signal
relay