3-98 ENGINE
REED VAVLE
Remove the PAIR valve covers.
Inspect the reed valves for the carbon deposit.
If the carbon deposit is found in the reed valve, replace the
PAIR valve with a new one.
PAIR VALVE
Inspect that air flows through the PAIR valve air inlet port
A to
the air outlet parts
B.
If air does not flow out, replace the PAIR valve with a new
one.
Connect the vacuum pump gauge to the vacuum port of the
PAIR valve as shown in the photograph.
Apply negative pressure slowly to the PAIR valve and inspect
the air flow.
If air does not flow out within the specification, the PAIR valve
is in normal condition.
If the PAIR valve does not function within the specification,
replace the PAIR valve with a new one.
( Negative pressure range: 65.3 kPa (490 mmHg)
) 09917-47010: Vacuum pump gauge
$
INSTALLATION
Rout the hoses properly. (!7-19)
Tighten the PAIR valve mounting bolt to the specified torque.
# PAIR valve mounting bolt: 10 N·m (1.0 kgf-m)
Use a hand operated vacuum pump to prevent the
PAIR valve damage.