EasyManua.ls Logo

Suzuki VL125 - Battery Maintenance and Specifications; Using a Multi Circuit Tester

Suzuki VL125
242 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ELECTRICAL SYSTEM 6-3
BATTERY
The MF battery used in this vehicle does not require mainte-
nance as inspection of electrolyte level and replenishment of water.
No hydrogen gas is produced during normal charging of the bat-
tery, but such gas may be produced when it is overcharged. There-
fore, do not bring fire near the battery while it is being charged.
Note that the charging system for the MF battery is different
from that of an ordinary battery. Do not replace with an ordi-
nary battery.
CONNECTING BATTERY
When disconnecting terminals from the battery for disassembly
or servicing, be sure to disconnect the negative (-) terminal first.
When connecting terminals to the battery, be sure to connect
the positive (+) terminal first.
If the terminal is found corroded, remove the battery, pour
warm water over it and clean with a wire brush.
Upon completion of connection, apply grease lightly.
Put a cover over the positive (+) terminal.
WIRING PROCEDURE
Route the wire harness properly according to “WIRE HAR-
NESS ROUTING”. (!7-10)
USING MULTI CIRCUIT TESTER
Use the Suzuki multi-circuit tester (09900-25008).
Use well-charged batteries in the tester.
Be sure to set the tester to the correct testing range.
Using the tester
Incorrectly connecting the + and - probes may cause the
inside of the tester to burnout.
If the voltage and current are not known, make measurements
using the highest range.
When measuring the resistance with the multi-circuit tester,
also measure the resistance with no-load. Sub-tract that re-
sistance from the resistance measured under load in order to
get the true resistance.
Measured
No load
=
Tr u e
[
resistance
][
resistance
][
resistance
]
When measuring the resistance with the multi-circuit tester,
becomes 10.00 M and “1” flashes in the display.
Check that no voltage is applied before making the measure-
ment. If voltage is applied, the tester may be damaged.
After using the tester, turn the power off.
" 09900-25008: Multi-circuit tester
NOTE:
* When connecting the multi circuit tester, install fine copper wires
(O.D is below 0.5 mm) to the back side of the lead wire cou-
pler and connect the probes of tester to them.
* Use a fine copper wire, the outer diameter being below 0.5
mm, to prevent the rubber of the water proof coupler from
damage.

Table of Contents

Related product manuals