EasyManua.ls Logo

Suzuki VL125 - Electrical System Troubleshooting

Suzuki VL125
242 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ELECTRICAL SYSTEM 6-7
TROUBLESHOOTING
Battery runs down quickly.
Check accessories which use excessive Accessories Remove accessories.
amounts of electricity.
are installed
No accessories
Check the battery for current Current leaks Short circuit of wire
harness
leaks. (! 6-8) Loose or disconnected wires
Faulty battery
No current leaks
Measure the charging voltage
between the battery terminals. Correct Faulty battery
(! 6-8) Abnormal driving condition
Incorrect
Measure the continuity of
the generator coil. No continuity Faulty generator coil or
(! 6-9)
disconnected lead wires
Continuity
Measure the generator no-load
voltage. (! 6-9) No good Faulty generator
OK
Inspect the regulator/rectifier. No good Faulty regulator/rectifier
(! 6-9)
OK
Inspect wirings. No good Short circuit of wire harness
Poor contact of couplers
OK
Faulty battery
Others
Battery overcharge Faulty regulator/rectifier
Faulty battery
Poor contact of generator lead wire coupler

Table of Contents

Related product manuals