PERIODIC MAINTENANCE 2-5
Remove the generator cover plug 1 and the timing inspection
plug 2.
" Generator cover plug: 15 N
.
m (1.5 kgf
.
m)
Timing inspection plug: 21 N
.
m (2.1 kgf
.
m)
NOTE:
To turn the crankshaft for clearance checking, and rotate in the
normal running direction. The spark plug should be removed.
Rotate the generator rotor to set the No.1 cylinders piston at
TDC of the compression stroke. (Rotate the rotor until the
R
line on the rotor is aligned with the center of hole on the gen-
erator cover.)
To inspect the No.1 cylinders valve clearance, insert the thick-
ness gauge to the clearance between the valve stem end and
the adjusting screw on the rocker arms.
# Valve clearance (when cold):
IN. : 0.10 0.15 mm
EX.: 0.18 0.23 mm
% 09900-20806: Thickness gauge
If the clearance is out of the specification, bring it into the speci-
fied range by using the special tool.
% 09917-10410: Valve adjust driver
7
Both right and left valve clearances should be as closely
set as possible.
Rotate the generator rotor 450 degrees (1-¼ turns) and align
the
F line on the rotor with the center of hole on the genera-
tor cover.
Inspect the No.2 cylinders valve clearance as the same man-
ner above.

Table of Contents