13. Electrical System
13-15
Starter motor removal
Disconnect the starter motor wire coupler.
Remove the starter motor lock bolts.
Remove the starter motor.
Starter motor inspection
Connect the battery positive terminal and
starter motor power terminal.
Put up iron between the battery negative
terminal and starter motor case.
Check the starter motor rotating condition.
Replace the starter motor if the rotating speed
is too slow.
Starter motor installation
Install in the reverse order of removal.
Caution
z Make sure the O ring is ok and coat it
with motor oil before installation.
Nut×1
Bolt×2
O-ring
To this chapter contents