A - 6 Symbol DS6708 Digital Scanner Product Reference Guide
ISBT 128 54h Enable 13-25
ISBT Concatenation F1h 41h Disable
13-26
Check ISBT Table F1h 42h Enable
13-27
ISBT Concatenation Redundancy DFh 10
13-27
Code 39
Code 39 00h Enable 13-28
Trioptic Code 39 0Dh Disable 13-28
Convert Code 39 to Code 32
(Italian Pharmacy Code)
56h Disable 13-29
Code 32 Prefix E7h Disable 13-29
Set Length(s) for Code 39 12h 13h 2 to 55 13-30
Code 39 Check Digit Verification 30h Disable 13-32
Transmit Code 39 Check Digit 2Bh Disable 13-32
Code 39 Full ASCII Conversion 11h Disable 13-33
Buffer Code 39 71h Disable 13-33
Code 93
Code 93 09h Disable 13-36
Set Length(s) for Code 93 1Ah 1Bh 4 to 55 13-36
Code 11
Code 11 0Ah Disable 13-38
Set Lengths for Code 11 1Ch 1Dh 4 to 55 13-38
Code 11 Check Digit Verification 34h Disable 13-40
Transmit Code 11 Check Digit(s) 2Fh Disable 13-41
Interleaved 2 of 5 (ITF)
Interleaved 2 of 5 (ITF) 06h Enable 13-41
Set Lengths for I 2 of 5 16h 17h 14 13-42
I 2 of 5 Check Digit Verification 31h Disable 13-44
Transmit I 2 of 5 Check Digit 2Ch Disable 13-44
Convert I 2 of 5 to EAN 13 52h Disable 13-45
Table A-1
Standard Default Parameters Table (Continued)
Parameter
Parameter
Number
Default
Page
Number
1
User selection is required to configure this interface and this is the most common selection.