Tasks
How to Get or Set the Input Comparator Voltage
Front Panel Command Line Interface
Not applicable
To set voltage value enter:
voltage [<value, 0 - 5V>] <CR>
To get voltage value enter:
voltage <CR>
Example to set the voltage for 1.5 volts:
Enter voltage 1.5 <CR>
Example, to get current voltage setting:
Enter voltage <CR>
Signal detection reference is 1.5 volts
How Display the System Version Information
Front Panel Command Line Interface
Not applicable
This is read only and cannot be changed through the CLI.
To get version value enter:
version <CR>
Example read out:
Micro-controller Firmware:
l Hydra/9611b DSP V01.01.RC4
l Sep 26 2011, 11:07:05
FPGA Firmware:
l Hydra/9611b FPGA 404
l V18.7.RC4
l 02/11/2011
How to Display/Clear (Latched) Faults
Front Panel Command Line Interface
Not applicable to view faults.
Press Alarm button to clear
faults
To view existing faults enter:
faults <CR>
To clear faults enter:
faults [clear] <CR>
How to Control Input Switching
Use this to select Input A, Input B or Automatic selection
Page 28 ..........................................................................9611B_UserGuide_RevA.pdf

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Symmetricom 9611B and is the answer not in the manual?

Symmetricom 9611B Specifications

General IconGeneral
BrandSymmetricom
Model9611B
CategorySwitch
LanguageEnglish