机床产品/Machine Tool Products
              –
              22/220 Series Controller Application Manual
Software InstallationData Backup/Restore–77
c.
i.
ii.
iii.
Ready state and retry.
Protections for drive parameter restoration of not packaged motor (supporting version: 10.116.54G,
10.118.0D)
During SB restoration, if a not packaged motor is included in the connected motor, a confirm
window will pop up with the content "drive parameter restoration of not packaged motor
could be dangerous. Sure to restore the parameters?". If selected F2 (Yes), all the items will be
restored: if selected F3 (Not), the parameters won't be restored but the other objects will.
During MB restoration, if a not packaged motor is included in the connected motor, the drive
parameter will be not unselected in default to avoid the restoration.
If alarm window "Pn724 input error, please run the Encoder-Rotor Offset correction" pops up
after the restoration is completed, it means the connected driver is in a previous version:
versions v2.6.5 (included) and before are not able to write Pn724 into not packaged motors.