EasyManua.ls Logo

Techkon SpectroDens - 2.2 Additional functions of SpectroDens Advanced

Techkon SpectroDens
101 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
51
CHAPTER 2 – Measurement functions
The thematic separation between densito-
metric and colorimetric functions is displayed
by a dotted line within the measurement
function window. CIE stands for the interna-
tional color institute Commission Internatio-
nale de l’Eclairage which publishes the stan-
dards for colorimetry.
The most popular color system in the printing
industry is the CIE L*a*b* color space. Every
color is precisely described by three values:
The L*-value stands for the luminance and can
have values between 0 (a theoretical, abso-
lute Black) and 100 (a theoretical, ideal White).
The a*-value describes the color value on the
Green/Red-axis (- a*: Green, + a*: Red) and the
b*-value the color value on the Blue/Yellow-
axis (- b*: Blue, + b*: Yellow).
Colorimetric L*a*b*-measurement on a blue
sample. The blue color has a low luminance
of L = 47.21 and a low portion of Red.
2.2 Additional functions of SpectroDens Advanced
CIE L*a* b*
The previously described measurement functions all were based on densitometry.
Thanks to the spectral performance of SpectroDens it is possible to calculate and dis-
play colorimetric values as well. Measurements in colorimetry modes have the advan-
tage of an absolute description of color based on characteristic values.
L* = 0
L* = 100
C*
h*
h* =
0h* = 180
L* = 50