RUN EXCITE-2008: Service & Maintenance Manual - rev. 1.3
Page 9.45
To correctly display the parameter values, you need to load them from the low kit, using
the “Read from low kit” function.
MESSAGE ON DISPLAY DESCRIPTION
Life AC M: Minutes x 10 of tread belt motor operation
Life DC M: Minutes of elevation motor operation
Life Kit H: Minutes x 10 of operation of the upper assembly
Life Kit L: Minutes x 10 of operation of the lower assembly
Tot. Km: Total km travelled
By pressing the RESET key on the side of the value, it is possible to reset the value of the selected
item.
Press HOME to confirm and save, FORWARD or BACK to scroll the pages.
9.5.3. ERRORS LOG
This function accesses the machine’s error history log.
In addition to the error history log, this function also includes the 3 sub-functions described below:
9.5.3.1. Read from low kit
To read the parameter values from the low kit memory and view them on the display, press READ
FROM LOW KIT key.
9.5.3.2. Reset Errors
To clear the error history in both the low and high kit memory, press RESET ERRORS key.
9.5.3.3. COM.Fault
This is a counter that display the number of errors in serial communication between the upper and
the lower kit. This counter increase each time a communication fault is detected.
To reset this counter, press RESET key on the side of the value.
To correctly display the parameter values, you need to load them from the low kit, using
the “Read from low kit” function.
For every error generated by the machine, the error history log records the information in the table
below:
• Error number;
• Error code;
• Tension at the error moment;
• Current when the error occurred
• Speed at the error monent Km/h.