Page 6.13
6.3.2. MANUAL TEST
This section groups together tests for manually checking the operation of certain peripheral devices.
After selecting the desired test item using the + and – speed keys, press ENTER to access the tests.
To exit test mode, hold down the CLEAR key for a few seconds.
The various manual tests are described below.
6.3.2.1. Man. Keyboard Test
The manual keyboard test checks the functioning of all the keys on the keyboard. After accessing
the test by pressing ENTER, the message “Press all buttons (beep=OK)” appears on the display.
Pressing each key will produce an audible signal, if a key does not produce the “beep” it means it is
not working properly.
6.3.2.2. Man. Inverter Test
The manual inverter test displays the values output by the inverter drive during movements of the
tread belt motor. The values displayed are:
Tread belt motor drive frequency (x100);
Current (x10);
Voltage.
During the test it is possible to change the speed using the + and – speed keys, to see the change in
the values of frequency, current and voltage.
6.3.2.3. Man. UpDown Test
The manual UpDown test displays the values output by the elevation motor drive during machine
incline movements. The values displayed are:
Machine incline position;
Number of pulses generated by the elevation motor encoder;
State of limit switch: if it is pressed, “MIN” is shown, nothing in the other condition.
During the test it is possible to vary the incline using the and elevation keys, to check that the