EasyManua.ls Logo

Technogym EXCITE Run 700 - Standard Settings

Technogym EXCITE Run 700
234 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
RUN EXCITE-2008: Service & Maintenance Manual - rev. 1.3
Page 9.47
9.5.5. STANDARD SETTINGS
This function allows you to reset the usage data of the machine and simultaneously set the default
values of the parameters of the inverter. To make the restoration of values, press the STANDARD
SETTINGS button
This function does not change the language and standard television set.
9.5.6. MAINS VOLTAGE
This function allows the user to choose the proper power supply voltage for the machine. To change
the selection, select the desired option among the ones in the list, directly touching on the Touch
Screen.
Mains Voltage
NO SET
100 VAC
120 VAC
230 VAC
Choosing “NO SET” value, when the machine is switched on it is necessary to insert the power
supply voltage provided by the electrical mains line.
REMEMBER to properly set the parameter each time you replace the Display.
9.5.7. READ/WRITE REGISTER
This function allows to displays and to modify the parameter values of type A, C, D, F, P, H and S.
To display a parameter value
1. Press ADRESS button;
2. input the desired parameter address, referring tot o tables at paragraph 9.4.6.2 “Config.
registers”;
3. Press READ FROM LOW KIT button;
4. the value set for the parameter will be displayed in the VALUE field.
To modify a parameter value:
1. Press ADRESS button;
2. input the desired parameter address, referring tot o tables at paragraph 9.4.6.2 “Config.
registers”;
3. press VALUE button;
4. input the desired value for the parameter;
5. press WRITE TO LOW KIT button;
Although the changes made to the parameters come into effect immediately, they are not
automatically stored in permanent memory; this requires a specific write operation
effected using the command C-0: at address 800 write the value “1”, following the
detailed instructions provided in paragraph 9.4.6.2 “Config. registers”.