3.2.3 Restore default IP and password
Press RST button for about 3 seconds, then the device will be rebooted and the IP address, username and password will be
restored to factory default.
3.2.4 Restore factory setting
Press RST button for about 7 seconds, then gateway will be rebooted and restored to factory setting.
3.3 LOCAL MAINTENANCE THROUGH CONSOLE PORT
To ensure easy maintenance, the device provides a standard RS232 console port, which has a Baud rate of 115200bps.
Users can log in the device to carry out maintenance-related configurations through the console port.
 Example: Log in device via Console Port
Step 1: Prepare a serial cable as follows (standard RS232, 115200bps);
Step 2: Connect the F port of the serial cable with the COM port of PC. If the PC does not have a COM port, please use a
USB-to-COM converting tool to connect the serial cable with the PC.
Step 3: Connect the M port of the serial cable with the console port of the device.
Step 4: Conduct configurations on login software.
Herein we take the PuTTY sofeware as an example. Detailed configurations are as follows: