EasyManua.ls Logo

Tekelec EAGLE 5 - PDBI Message Error Codes

Default Icon
181 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
PDBI Message Error Codes
Table 42: PDBI Message Error Codes lists the error codes, associated text generated by the PDBI, and
recommended actions.
Table 42: PDBI Message Error Codes
Recommended ActionTextError Code
No action necessary. This indicates a
successful response from the PDBA.
PDBI_SUCCESS =00
Contact Tekelec.PDBI_INTERNAL_ERROR = 10011001
Establish an active connection before
re-issuing this command.
PDBI_NOT_CONNECTED1002
No action necessary. This is a redundant
connection attempt.
PDBI_ALREADY_CONNECTED1003
Refer to the data section of the return
message to determine the cause of the parse
failure.
PDBI_PARSE_FAILED1004
Wait for write transaction to close before
re-attempting this command.
PDBI_WRITE_UNAVAIL1005
No action is necessary unless the IP address
of this PDBI client should have WRITE
PDBI_NO_WRITE_PERMISSION1006
access permissions. If that is the case, add
WRITE permissions for the IP address of
the PDBI client.
Contact Tekelec. This indicates that the
Active PDB has lost contact with Standby.
PDBI_NO_MATE1007
Connect to the Active PDBA for write
operations.
PDBI_STANDBY_SIDE1008
Open a write transaction before retrying
this command
PDBI_NO_ACTIVE_TXN1009
Wait for the transaction to complete before
re-attempting the switchover.
PDBI_ACTIVE_TXN1010
161
910-6022-001 Revision A, March 2011
PDBI Message Error CodesProvisioning Database Interface Manual

Table of Contents

Other manuals for Tekelec EAGLE 5