EasyManua.ls Logo

Tekelec EAGLE 5 - Table 3: Connect Response Return Codes

Default Icon
181 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Note: If a connection is configured to send asynchronously SM Reports and processes
a command that takes a long time, SM Reports will be suspended until after the long
running command is completed. For example, if a client connects with a dsmrptfreq
of 1 and then requests a retrieve of millions of DNs, the SM Reports will be suspended
until the retrieve command has completed. Once the SM Reports resume they will
continue at the configured frequency..
1 86400 Send the Service Module card Report in this many
seconds.
Values:
Request syntax :
Connect([iid XXXXX,] [version 1.0], [rspsize <1..32>], [switchactn <none/close>],
[endchar <null/newline>], [idletimeout <none/1..44640/[00-44640]:[00-59]>],
[txnmode <normal/single>], [dsmrpt <no/yes>], [dsmrptperc <1..100>],
[dsmrptfreq <1..86400>])
Note: The limit is 44640:00.
Response
The Connect response message indicates whether or not the PDBA is capable and willing to accept a
new connection. If the connection is accepted, the data section in the response indicates the connection
ID (iid) that was assigned and whether the PDBA connected to was running as the Active or Standby
PDBA.
The return codes listed in this topic indicate the result of the Connect request. See PDBI Message Error
Codes for the recommended actions to help resolve the error related return codes.
Table 3: Connect Response Return Codes
Data Section ContentsDescriptionTextReturn
Code
The assigned connection
id and Active status are
returned.
Everything worked.SUCCESS
0
data (connectId
########, side
active/standby)
NONEA connect request was sent
on a socket that already had
an established connection.
ALREADY_CONNECTED
1003
The offending field is
returned in the data
section:
One of the fields specified
had an invalid value.
INVALID_VALUE
1012
55
910-6022-001 Revision A, March 2011
PDBI Request/Response MessagesProvisioning Database Interface Manual