Ou
tput can be also used to generate signals with desired amplitude. Resistor could be for example 4.7kΩ.
8.17.4.5 Relay output
Relay output has two pins: COM and NO. When the relay is not energized (output not active), these pins are
disconnected. One the relay is energized (output active) these pins are become connected together.Relay output is not
intended to drive AC voltages.
Maximum DC voltage across relay contacts
24V
Maximum relay DC current
4A
E
xample of connecting alarm siren to the relay output: