5-4
Internally mounted accessories
Type of breaker
Standard
For microload 1
AC (V) DC (V)
Minimum
load
DC(V)
Minimum
load
Voltage
(V)
Current (A)
Voltage
(V)
Current (A)
Voltage
(V)
Current (A)
Resistive
load
Inductive
load
Resistive
load
Inductive
load
Resistive
load
S160-SD, S160-GD, S160-SDN,
S250-SD, S250-GD, S250-SDN,
S400-ND, S800-ND, S1000-ND,
PVE160-SDL, PVS160-SDL, PVS250-SDL,
PVS160-SNL, PVS250-SNL, PVS160-SDH, PVS250-SDH,
PVS160-SNH, PVS250-SNH, PVS160-GDH, PVS250-GDH,
PVS400-NDL, PVS400-NNL,
PVS400-NDH, PVS400-NNH,
PVS800-NDL, PVS800-NNL, PVS800-NDH,
PVS800-GDH, PVS800-NNH
480
――
250
――
DC15V
100mA
30
0.1
DC5V
1mA
250 3 2 125
0.40.05
125 3 2 30 3 2
XS1250ND, XS1600ND,
XS2000ND, XS2500ND, XS3200ND
480 3 2 250
0.30.3
DC5V
160mA
DC30V
26.7mA
30
0.1
DC5V
1mA
DC30V
1mA
250 5 5 125
0.60.6
125 5 5 30 5 4
3. Ratings data of auxiliary and alarm switches
• The applicable load of the switch shall be no larger than the rating and no smaller than the minimum load.
Ratings of AX and AL
Note: 1 This is a custom-made product. When ordering for this product, specify that it is intended for microlead use.
Note: 2 The inductive load means power factor of no smaller than 0.4 for AC and time constant of no larger than 7 ms for DC.
Type of breaker
Peak exciting current, A
Rated
voltage
AC (V) DC (V)
100-120 200-240 380-450
24 48
100-120 200-240
S160-SD, S160-GD, S160-SDN,
S250-SD, S250-GD, S250-SDN,
S400-ND, S800-ND, S1000-ND,
PVE160-SDL, PVS160-SDL, PVS250-SDL,
PVS160-SNL, PVS250-SNL, PVS160-SDH,
PVS250-SDH,PVS160-SNH, PVS250-SNH,
PVS160-GDH, PVS250-GDH
PVS400-NDL, PVS400-NNL,
PVS400-NDH, PVS400-NNH,
PVS800-NDL, PVS800-NNL, PVS800-NDH,
PVS800-GDH, PVS800-NNH
0.014 0.014 0.0065 0.03 0.03 0.011 0.011
4. Shunt trip device (SH)
Ratings of SHT
Notes:
3: Exclusive use for 200V class and 400V class.
(1) The permissible voltage range is from 70% to 110% of the rated voltage. Ensure that the voltage does not drop exceeding the permissible voltage range when SHT is actuated.
(2) Breaker contacts usually start opening within 30 ms after the rated voltage is applied to the breaker.
Type of breaker
Peak exciting current, A (AC60Hz)
Rated
voltage
AC (V) DC (V)
100-115 200-480
24 48
100-115 200-230
XS2000ND, XS2500ND, XS3200ND
1.1
0.4(AC200-240V)
0.93(AC380-480V)
3
2.52 1.55 0.67 0.35
XS1250ND, XS1600ND
1.10.93 2.52 1.55 0.67 0.35
5. Undervoltage trip device (UV)
Note: 1: No UVT controller is required.
(1) Tripping voltage is from 35% to 70% of the rated voltage. Resettable voltage is 85% or less of the rated voltage.
Note: 1: No UVT controller is required.
(1) Tripping voltage is from 35% to 70% of the rated voltage. Resettable voltage is 85% or less of the rated voltage.
(1)Ratings of UVT with Inst
Rated
voltage
AC (V)
100-110 200-220 380-415
24
100-120 200-240
Power supply capacity, VA 1 Exciting current, mA 1
DC (V)
S800-ND, S1000-ND,
PVS800-NDL, PVS800-NNL, PVS800-NDH,
PVS800-GDH, PVS800-NNH
1.52.42.1
29 13 11
115-120 230-240 440-450
1.62.92.3
Type of breaker
Type of breaker
Power supply capacity, VA 1
Rated
voltage
AC (V) DC (V)
100-120 200-240 380-450
24
100-120 200-240
S400-ND,
PVS400-NDL, PVS400-NNL,
PVS400-NDH, PVS400-NNH
1.42.82.3
23 10 10
Exciting current, mA 1
S160-SD, S160-GD, S160-SDN,
S250-SD, S250-GD, S250-SDN,
PVE160-SDL, PVS160-SDL, PVS250-SDL,
PVS160-SNL, PVS250-SNL, PVS160-SDH, PVS250-SDH,
PVS160-SNH, PVS250-SNH, PVS160-GDH, PVS250-GDH
1.41.52.3
23 10
3.5
Connectiondiagram
andterminalNo.
Connectiondiagram
andterminalNo.
Connectiondiagram
andterminalNo.
D1 D2
D1 D2
Connectiondiagram
andterminalNo.
Without anti-burn swi
C2 C1
With anti-burn switch
S2S1
〜
(−)
〜
(+)