November 2021 Maintenance Manual
Programmed Maintenance Procedures
Part No. 1305686GT Scissor Lifts 73
P0-7
Kubota Engine Maintenance Under 1000 Hours
Additional engine maintenance is required. Refer to the Programmed Maintenance Inspection Report for
the specific intervals that apply.
Required maintenance procedures and additional engine information are available in the manufacturer's
manuals. Refer to Specifications, Engine Operator and Maintenance Manuals.
This maintenance schedule applies to the following Kubota Engines:
Kubota D-1105-E3B Kubota WG972
Kubota Engines Hour Intervals
Procedure
∅ =
Not required
Daily 50 75 100 150 200
400 500 800
Coolant level - check
Oil level - check
Oil, fuel and coolant systems - check for leaks
Fuel system filter/water separator inspect/drain
Fuel hoses and clamp bands - check
Fan belt tension and damage - check
Battery electrolyte level - check
Spark plug - check
Air cleaner element - clean
(Replace the element after 6 times cleaning)
Fuel filter (element type) - clean
Oil filter cartridge - replace,
Engine oil - replace
Radiator hoses and clamps - check
Intake air line - check, D-1105
Fuel filter cartridge - replace
Air cleaner element - replace
Fan belt - replace
Cleaning of water jacket (radiator interior)
Removal of sediment in fuel tank
Damage in electric wiring and loose connections - check
Valve clearance - check

Table of Contents

Other manuals for Terex Genie GS-1330m

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Terex Genie GS-1330m and is the answer not in the manual?

Terex Genie GS-1330m Specifications

General IconGeneral
BrandTerex
ModelGenie GS-1330m
CategoryLifting Systems
LanguageEnglish

Related product manuals