November 2021 Maintenance Manual
Programmed Maintenance Procedures
Part No. 1305686GT Scissor Lifts 87
P3-1
Perform Engine Maintenance
3000 Hours
Engine specifications require that this procedure
be performed every 3000 hours.
Required maintenance procedures and additional
engine information are available in the
manufacturer's manuals. Refer to Specifications,
Engine Operator and Maintenance Manuals.
Deutz Models
D2011L03i
Charge air cooler entry- drain lube
oil/condensate
Injection valve- replace
D 2.9 L4, TD 2.2 L3
Cooling system coolant - replace
V-rib belt and tensioning pulley - replace
Ford Models
Coolant filler cap - clean/replace
Perkins Models
Water pump - inspect
Fuel Injector - test/change
Cooling system coolant (Heavy Duty) -
change
Kubota Models
Injection pump - check
Fuel injection timing - check