November 2021 Maintenance Manual
Annual Maintenance Procedures
Part No. 1305686GT Scissor Lifts 67
A-8
Check the Steer Yoke King Pin
Fastener Torque - GS-84, GS-90
Genie specifications require that this procedure be
performed annually.
Maintaining proper torque is essential to safe
machine operation. Improper bolt torque could
result in an unsafe operating condition and
component damage.
Note: Perform this procedure on both sides of the
steer axle.
1 Check the upper and lower steer yoke king
pin fastener torque.
Note: Loctite
®
243™ threadlocker must be applied
to the retaining fasteners whenever they are
removed or replaced.
1 retaining fasteners
2 rod end
3 king pin
Torque specifications
44 ft-
lbs
60 Nm
1
2
3
1
2
3