6. AVAILABLE DEVICES
6.1 MACHINE ELECTRONIC CONNECTION (ALL.089)
When machines be equipped with an electronic connection package, this device allows to use multiple
machines connected between them, controlled and operated by a single operator for the main working
parameters.
Is possible to connect a maximum 4 machines between them, with the possibility to work with 4
independent ropes configurations.
The machines must be connected through a special connecting cable; the un-used plugs on the first and
on the last machine (right and left) must always be closed with the related caps.
To grant the continuous connection of the machines, a special protection device must be provided for the
connection cables, to avoid accidental disconnection of the communication between the machines.
WARNING
Connect the connection cables before switching on and using connected
machines. The cables must be connected when the machine have DIESEL OFF.
WARNING
If the operator disconnect the machine connection cables, during operation,
you will have the immediate emergency stop of all connected machines.
WARNING
Before using the machines connected to each other, make sure that the fine
braking gear configuration is HIGH-PULL in each machine.