HYDRAULIC PULLER-TENSIONER PT1250
Manual: MI-PT1250-050-01-IT Date: 06.11.2017 Author: AT Page: 60 of 69
6.1.5 CONDITIONS OF ALARM WITH RELATED MACHINES
When using attached machines some situations generate an alarm, stopping the stringing operations or
blocking the diesel engine of the machines.
STOP IN EMERGENCY
By pressing the emergency stop on the panel in one of the connected machines, the engine of each
single electronically connected machine will stop.
To reset the alarm, move the neutral joystick in the MASTER machine, turn off the emergency stop in the
machine in an emergency and turn on the diesel engines of the individual machines.
CAN-BUS DISCONNECTION BETWEEN MACHINES
In the case of disconnected cables between machines (ex. loose plugs, accidental cutting of a cable, ...),
tensioning operations stop in all connected machines.
If disconnection will happen with powered motors, disconnecting the connecting cables the diesel engines
will turn off.
To reset the alarm, move the neutral joystick to the MASTER machine and check the cause of the failure.
WARNING
Disconnecting the connection cable is equal to pressing the emergency button.
When disconnecting the cable, all diesel engines of the connected machines
will immediately turn off.