658
Appendix A: System Routines — Link
TI
-
89 / TI
-
92 Plus Developer Guide
Not for Distribution
Beta Version January 26, 2001
LIO_RecvData
Declaration:
WORD
LIO_RecvData
(BYTE *
data
, DWORD
count
, DWORD
timeout
)
Category(ies):
Link
Description:
Receive data from the link port.
Inputs:
data
Pointer to buffer where data will be stored.
count
Number of bytes to receive.
timeout
If 0, receive until all data is sent or an error occurs. If
nonzero, quit waiting after a delay of
timeout
.
Outputs:
Returns non-0 if an error occurs. Otherwise returns 0.
Assumptions:
None
Side Effects:
None
Availability:
All versions of the TI-89 / TI-92 Plus.
TI-89 / TI-92 Plus
Differences:
None
See Also: LIO_SendData
Example:
if (error = LIO_RecvData(msg, len+2, ONE_SECOND * 2))
return error;