EasyManua.ls Logo

Thermal Arc 500 - Rear Panel (All Models)

Thermal Arc 500
100 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
POWERMASTER 500, 500P, 350, 350P
4-6
March 17, 2006
4.04 Rear Panel (All Models)
St. Louis, MO USA
MADE IN MALAYSIA
WELDING OUTPUT
75V
ENERGY INPUT
50/60HZ3
U
1
I
1MAX
I
1eff
208 V
230 V
400 V
460 V
88
82
43
39
68
64
33
30
IP23S
50/60HZ1
AUXILLARY POWER OUTPUT
120 V
24 V
10A
10A
100%
100%
F1
F2
S
5
1
2
3
4
5
Art # A-06859
6
Figure 4-3: Rear Panel
1. 14 Pin Receptacle: This receptacle allows the power
source to interface with wire feeders, and remote
controls such as a foot pedal. This receptacle provides
auxiliary power, contactor control for energizing the
output of the power source, and remote output control.
The pinout is as follows:
A) 24 VAC auxiliary power high side
B) 24 VAC Contactor circuit, (closure between pin A
and pin B will energize output).
C) Remote control maximum (top side of remote pot.)
D) Control circuit common
E) Remote control in (wiper of remote pot., 0 to 10
Volts). CV mode: 0 to 10 Volts gives 10 – 44 Volts
of output. CC mode: 0 to 10 Volts gives 5 – 560
Amps of output.
F) Scaled output current signal: Ifb = 100 Amps/Volt
G) 24/115 VAC neutral
H) Output voltage signal: 10 Volts/Volt
I) 115 VAC auxiliary power high side
J) 115 VAC Contactor circuit, (closure between pin I
and pin J will energize output).
K) Chassis ground
L) N/C
M) N/C
N) N/C
2. 19 Pin Receptacle: This receptacle allows the power
source to interface with wire feeders, and remote
controls such as a foot pedal. This receptacle provides
auxiliary power, contactor control for energizing the
output of the power source, and remote output control.
The pinout is as follows:
A) Contactor circuit (+15 Volts)
B) Contactor circuit in, (closure between pin A and
pin B will energize output).
C) Scaled output voltage signal: Vfb = 10 Arc Volts/
Volt
D) 24 VAC auxiliary power high side
E) 115 VAC auxiliary power high side
F) 24/115 VAC neutral
G) Chassis ground
H) Remote control maximum (top side of remote pot.)
J) Remote control in (wiper of remote pot., 0 to 10
Volts). CV Mode: 0 to 10 Volts gives 0 – 44 Volts
of output. CC Mode: 0 to 10 Volts gives 0 – 560
Amps of output.
K) Remote control minimum (bottom side of remote
pot.)
L) Control circuit common
M) Arc Established = +12 Volts
N) Control circuit common
P) 24 VAC auxiliary power high side (same as pin D)
R) 24/115 VAC neutral (same as pin E)
S) N/C
T) N/C