EasyManuals Logo

THORLABS DCU223 SERIES User Manual

THORLABS DCU223 SERIES
420 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #165 background imageLoading...
Page #165 background image
160 DCx camera
© 2010 Thorlabs
7.3.26
is_GetCaptureErrorInfo
USB 2.0
USB 2.0
Syntax
INT is_GetCaptureErrorInfo (HIDS hCam,
UC480_CAPTURE_ERROR_INFO* CaptureErrorInfo,
UINT SizeCaptureErrorInfo)
Description
is_GetCaptureErrorInfo() returns detail information on errors that occurred during an image
capture process. The function lists all errors that occurred since the last call of the
is_ResetCaptureErrorInfo() function.
Input Parameters
hCam
Camera handle
CaptureErrorInfo
Structure of the _UC480_CAPTURE_ERROR_INFO type that is filled by the DCx
camera driver.
This structure then contains the error list.
SizeCaptureErrorInfo
Indicates the size of the CaptureErrorInfo structure.
Contents of the _UC480_CAPTURE_ERROR_INFO Structure
DWORD
dwCapErrCnt_Total
Returns the total number of errors occurred since the last reset.
BYTE
reserved[60]
Reserved for an internal function
DWORD
adwCapErrCnt
_Detail[CapErr]
This array returns the current count for each possible error. The
possible errors are listed below. To query the counter of a specific
error type, pass its definition in the CapErr parameter.
207

Table of Contents

Other manuals for THORLABS DCU223 SERIES

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the THORLABS DCU223 SERIES and is the answer not in the manual?

THORLABS DCU223 SERIES Specifications

General IconGeneral
BrandTHORLABS
ModelDCU223 SERIES
CategorySecurity Camera
LanguageEnglish

Related product manuals