18. MISSING LINE MEASUREMENT
98
2. Sight the starting position, and press [MEAS] to
start measurement.
Press [STOP] to stop measurement.
When measurement data already exists the
screen of step 3 is displayed and measurement
starts.
3. Sight the next target and press [MLM] to
begin observation. Slope distance, grade,
horizontal distance and height difference
between multiple points and the starting
position can be measured this way.
•Press [MEAS] to re-observe the starting
position. Sight the starting position and
press [MEAS].
When [MOVE] is pressed, the last target
measured becomes the new starting
position to perform missing line
measurement of the next target.
"18.2 Changing the Starting Point"
4. Press {ESC} or tap the cross in the top-right
corner to end missing line measurement.
Results for current point
Results for measurement between starting
position and second target