EasyManua.ls Logo

Topcon OS-101 - Page 125

Topcon OS-101
165 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
119
20. CHANGING THE SETTINGS
3. "SHV" and "NEZ" tabs of <Set out Coords>
Page 1 [ OK ] [ --- ][CNFG] [MEAS]
Page 2 [ --- ] [ --- ] [ --- ] [ --- ]
Page 3 [ --- ] [ --- ] [ --- ] [ --- ]
The following functions can be allocated to the softkeys.
[ --- ] : No functions set
[MEAS] : Distance and angle measurement
[CNFG] : Set setting out accuracy (can only be allocated to 2 and 3 above)
[SHV] : Switch the "SHV" tab and "SHVdist" tab (can only be allocated to 1 above)
[SHVR] : Switch distance mode between slope distance (SD)/horizontal distance (HD)/height
difference (VD)/REM (R) in setting out screens. The capitalized letter in the softkey
indicates the currently selected mode (can only be allocated to 2 above).
[OK] : Terminate setting out measurement for the selected setting out point and return to
<Key in coord>. This setting out point will be removed from the list (can only be
allocated to 3 above).
[0SET] : Set horizontal angle to 0°
[H-SET] : Set required horizontal angle
[R/L] : Select horizontal angle right/left. The capitalized letter in the softkey indicates the
currently selected mode.
[ZA / %] : Switch between zenith angle/slope in %. The capitalized letter in the softkey indicates
the currently selected mode.
[HOLD] : Hold horizontal angle/release horizontal angle
[CALL] : Display final measurement data
[HVOUT-S] : Output angle measurement results to an external device (SET format)
[HVDOUT-S] : Output distance and angle measurement results to an external device (SET format)
[NEZOUT-S] : Output coordinates data to an external device (SET format)
[HVOUT-T] : Output angle measurement results to an external device (GTS format) (can only be
allocated to 1 above)
[HVDOUT-T] : Output distance and angle measurement results to an external device (GTS format)
(can only be allocated to 1 above)
[NEZOUT-T] : Output coordinates data to an external device (GTS format) (can only be allocated to
1 above)
[F/M] : Switch distance units between meters/feet
[HT] : Set the instrument station, coordinates and instrument height
[S-LEV] : Return signal
[TILT] : Display tilt angle
[EDM] : EDM settings
[MENU] : Display <Menu> (coordinate measurement, setting out measurement, offset
measurement, REM measurement, missing line measurement, resection, area
calculation)
[COORD] : Coordinates measurement
[S-O] : Setting-out measurement
[OFFSET] : Offset measurement
[A-OFS] : Angle offset measurement
[D-OFS] : Distance offset measurement
[2D-OFS] : Offset/2D measurement
[MLM] : Missing line measurement
[REM] : REM measurement
[RESEC] : Resection measurement
[AREA] : Surface area measurement

Table of Contents

Related product manuals