26. SPECIFICATIONS
148
Rapid measurement:
(6 + 2ppm X D) mm (0.3 to 200m)
(8 + 10ppm X D) mm (over 200 to 350m)
(15 + 10ppm X D) mm (over 350 to 500m)
(Reflectorless (Gray))
*6
Fine measurement
(3 + 2ppm X D) mm (0.3 to 100m)
(5 + 10ppm X D) mm (over 100 to 170m)
(10 + 10ppm X D) mm (over 170 to 220m)
Rapid measurement:
(6 + 2ppm X D) mm (0.3 to 100m)
(8 + 10ppm X D) mm (over 100 to 170m)
(15 + 10ppm X D) mm (over 170 to 220m)
(D: measurement distance; Unit: mm)
Measurement mode Fine measurement (single/repeat/average)/Rapid measurement
(single/repeat)/Tracking (selectable)
Measuring time (fastest time under good atmospheric conditions
*2
, no
compensation, EDM ALC at appropriate setting, slope distance)
Fine measurement: less than 1.7 sec + every 0.9 sec or less
Rapid measurement: less than 1.4 sec + every 0.7 sec or less
Tracking measurement: less than 1.4 sec + every 0.3 sec or less
Atmospheric correction
Temperature input range: - 30 to 60°C (in 0.1°C step)/ - 22 to 140°F (in 1°F step)
Pressure input range: 500 to 1,400 hPa (in 1hPa step)
375 to 1,050 mmHg (in 1mmHg step)
14.8 to 41.3 inchHg (in 0.1inchHg step)
ppm input range: -499 to 499 ppm (in 1 ppm step)
Prism constant correction -99 to 99 mm (in 1 mm step)
0mm fixed for reflectorless measurement
Earth curvature and refraction correction
No/Yes K=0.142/Yes K=0.20 (selectable)
Sea level correction No/Yes (selectable)
*1: Slight haze, visibility about 20 km, sunny periods, weak scintillation.
*2: No haze, visibility about 40 km, overcast, no scintillation.
*3: Measurement at -30 to -20°C (-22 to -4°F) (Low Temperature Model)/50 to 60°C (122 to 140°F)
(Standard Model)
*4: Figures when the laser beam strikes within 30° of the reflective sheet target.
*5: Figures when using Kodak Gray Card White side (reflection factor 90%) and brightness level is
less than 30000 lx (a little cloudy).
*6: Figures when using Kodak Gray Card Gray side (reflection factor 18%) and brightness level is less
than 30000 lx (a little cloudy).
*5,*6:When performing reflectorless measurement, the possible measurement range and precision
will change depending on the target reflection factor, weather conditions and location
conditions.
*7: Face the prism toward the instrument during the measurement with the distance at 10 m or less.
*8: At the time of the tracking measurement.