75
15. RESECTION MEASUREMENT
7. If there are problems with the results of a point,
align the cursor with that point and press [OMIT].
“OMIT” is displayed to the right of the point.
Repeat for all results that include problems.
8. Press [RE CALC] to perform calculation again
without the point designated in step 7 The result
is displayed.
If there are no problems with the result, go to step
9.
If problems with the result occur again, perform
the resection measurement from step 4.
•Press [RE_OBS] to measure the point
designated in step 7.
If no points are designated in step 7, all the
points or only the final point can be observed
again.
•Press [ADD] in the second page when there is a
known point that has not been observed or when
a new known point is added.
9. Press [OK] to finish resection measurement and
return to <Resection/Menu>. Only Z (elevation) of
the instrument station coordinate is set. N and E
values are not overwritten.