(2) Adjusting Calibration
1 By pressing the UP or DOWN arrow keys on the
RC-300W, move the rotating laser beam up or down
as necessary until the center bar on the LS-70A
display is lit. (This will be the same position as
center of “X:1” and “X:2”.)
While the beam is moving, RC-300W displays
“ADJUSTING”.
2 When the center bar lit on the LS-70A, press the
[ENT] key on the RC-300W.
The correction value will be calculated by the RT-
5SW and transmitted to the RC-300W. When the
transmission is completed, the display shows
“PUSH (ent) KEY”.
X:2
Move the X2 rotating laser until the center bar of the
LS-70A display is lit.
When the center bar is lit, press [ENT].
X:3
PUSH KEY
center
X2 rotating laser
beam
Confirm the value, press [ENT].