Loading...
SprayPro™Monitor
TheSprayPromonitordisplaysandmonitorsvarioussystem
performancedatasuchasvehiclespeedandapplicationrates.
Itdoesnotcontroltheapplicationrate.
ThemonitorhasanLCDscreenthatdisplaysthedatayou
select,aselectiondial,and4buttonsforcalibratingthe
monitor(Figure38).
Figure38
1.LCDscreen
6.Applicationrate11.Reset,calibrationbutton
16.Selectunits
2.Selectiondial7.SubArea12.Calibrate,calibrationbutton
17.Width
3.Totalarea8.Distance13.Decrease,calibration
button
18.Speedcalibration
4.Speed9.Subvolume
14.Increase,calibrationbutton19.Flowmetercalibration
5.Unitsofmeasure
10.Totalvolume15.Boomselection20.LED
MonitorDisplaySelectionDial
UsethedialtosettheLCDscreendisplaytothefollowing:
Totalarea
Displaysthetotalacres(US),hectares(SI),orsqfeet
(TURF)thatyouhavecoveredsinceyoulastpressedthe
Resetcalibrationbuttonforthissetting.
Speed
Displaysthegroundspeedinmilesperhour(iftheUnits
ofMeasureissettoUSorTURF)orkilometersperhour
(iftheUnitsofMeasureissettoSI).
UnitsofMeasure
Displaysthecurrentmeasurementunitselectionas
follows:
US(UnitedStatesmeasuringsystem)
SI(metricsystem)
TURF(asUSbutthevolumesareinUSgallonsper
1000sqftinsteadofUSgallonsperacre)
ApplicationRate
DisplaystheapplicationrateinUSgallonsperacre
(US),litersprehectare(SI),orUSgallonsper1000sqft
(TURF).
SubArea
Displaysthetotalacres(US),hectares(SI),orsqfeet
(TURF)thatyouhavecoveredsinceyoulastpressedthe
Resetcalibrationbuttonforthissetting,withoutaffecting
theTotalAreadisplay.IfyoupresstheResetcalibration
button,theSubVolumeresets.
Distance
Displaysthedistanceyouhavetraveledinfeet(USand
TURF)ormeters(SI)sinceyoulastpressedtheReset
calibrationbuttonforthissetting.
SubVolume
DisplaysthetotalvolumeinUSgallons(USandTURF)
orliters(SI)thatyouhaveappliedsinceyoulastpressed
theResetcalibrationbuttonforthissetting,without
affectingtheTotalVolumedisplay.IfyoupresstheReset
calibrationbutton,theSubArearesets.
TotalVolume