ProPass 200 Electrical SystemPage 4 -- 15
Problem Possible Causes
Rear option does not function (machines with
electronic hydraulics).
NOTE: Start button on remote must be pushed twice to
activate rear option. Also, check wireless remote LCD
display and base unit LED’s for help in troubleshooting.
Wireless remote has not been turned ON.
Wireless remote has timed out due to thirty (30)
minutes of inactivity.
Wireless remote settings are incorrect.
Proportional flow valve coil (PV1) or circuit wiring is
faulty.
Hydraulic problem exists (see Chapter 3 -- Hydraulic
System).
Wireless remote is faulty.
Base unit is faulty.
Floor does not function (machines with standard
hydraulics).
FloorswitchinpendantisOFF.
Floor switch in pendant is faulty.
Floor solenoid valve coil or circuit wiring is faulty.
Hydraulic problem exists (see Chapter 3 -- Hydraulic
System).
Floor does not function ( machines with electronic
hydraulics).
NOTE: Check wireless remote L CD display and base
unit LED’s for help in troubleshooting.
Wireless remote has not been turned ON.
Make sure that floor start--up procedure has been
correctly completed with remote.
Wireless remote has timed out due to thirty (30)
minutes of inactivity.
Wireless remote settings are incorrect.
Proportional solenoid valve coil (SP1) or circuit wiring
is faulty.
Hydraulic problem exists (see Chapter 3 -- Hydraulic
System).
Wireless remote is faulty.
Base unit is faulty.